How to fix “The extended attributes did not fit in the buffer. [ERROR_EAS_DIDNT_FIT (0x113)]” – Error Code 275
Error Code 275
Error code Error Code 275
is a common Windows issue that typically arises from “The extended attributes did not fit in the buffer. [ERROR_EAS_DIDNT_FIT (0x113)]”.
Overview
The error message “The extended attributes did not fit in the buffer. [ERROR_EAS_DIDNT_FIT (0x113)]” is associated with Error Code 275. This error occurs when the extended attributes (EAs) of a file or directory exceed the available buffer size. EAs are metadata attached to files or directories that store additional information, such as access control lists (ACLs), file ownership, and creation and modification timestamps. When the buffer allocated to store the EAs becomes insufficient, Error Code 275 is thrown.
Identifying the Problem
Error Code 275 can manifest in various scenarios:
- When accessing files or directories with a large number of EAs attached.
- During operations that modify the EAs of a file or directory, such as adding or deleting ACLs.
- While attempting to copy or move files or directories with extensive EAs to a destination with limited storage space.
Common Fixes
Method 1: Increase Buffer Size
- Open the Command Prompt as an administrator.
- Enter the following command:
fsutil behavior set eas max-ea-size=<new_size>
- Replace
<new_size>
with an appropriate value in bytes, ensuring it is larger than the current size of the EAs causing the error. - Restart your computer.
Method 2: Use the Robocopy Command
The Robocopy command can handle the transfer of files with large EAs more efficiently. To use this method:
- Open the Command Prompt as an administrator.
- Enter the following command:
robocopy <source_path> <destination_path> /XJ
- Replace
<source_path>
and<destination_path>
with the appropriate source and destination paths.
Advanced Troubleshooting
Method 3: Disable EAs
Disabling EAs can resolve the error if you do not require the extended information they store. To do this:
- Open the Command Prompt as an administrator.
- Enter the following command:
fsutil behavior set disable-eas 1
- Restart your computer.
Method 4: Reduce EA Size
If possible, reduce the size of the EAs attached to the file or directory causing the error. This can be done by removing unnecessary ACLs or other EA data.
Conclusion
Error Code 275 can be resolved by increasing the buffer size, using the Robocopy command, disabling EAs, or reducing EA size. By implementing these solutions, you can restore the proper functioning of your system and ensure the integrity of your files and directories. To prevent future occurrences of Error Code 275, consider implementing a policy to limit the number of EAs attached to files and directories and using storage devices with sufficient capacity to accommodate extended attributes.